A Diaphragm Type Fiber Bragg Grating Vibration Sensor Based on Transverse Property of Optical Fiber With Temperature Compensation

Abstract
This paper has presented a novel diaphragm-type fiber Bragg grating (FBG) vibration sensor with a small mass and an excellent sensitivity through the use of the transverse property of a tightly suspended optical fiber with two fixed ends. Two suspended optical fibers that were embedded with an FBG element each, have been arranged symmetrically along the both sides of the diaphragm in a parallel manner, and their middle points were connected with the two surfaces of the mass by rigid thin rods to sense vibration. The theoretical model of the presented sensor has been derived, and its sensing characteristics have been analyzed by numerical simulation to determine the physical parameters. Experiments have been conducted to show that its sensitivity is 31.25 pm/g within a working bandwidth range of 10~150 Hz. The linearity and relative sensitivity errors are respectively 2.21% and ยฑ10%. The experimental resonant frequency of 300 Hz is consistent with the theoretical value, which has verified the effectiveness of the proposed theoretical model. The temperature response of this sensor has decreased to 1.32 pm/โ„ƒ in the range of 30~90 โ„ƒ after implementing the temperature compensation. Compared with the existing diaphragm-enabled FBG vibration sensors, the proposed sensor enables to support the easy implementation of distributed measurement, and the small mass allows for detection on mass-sensitive structures.

Safety-Enhanced Motion Planning for Flexible Surgical Manipulator Using Neural Dynamics

Abstract
Robot-assisted systems have been developed for minimally invasive surgical procedures, which bring tremendous benefits for patients, such as less trauma, less bleeding, and shorter recovery time. Among the contemporary surgical robotic manipulators, flexible serpentine manipulator shows great advantages on operating with complicated nonlinear anatomical constraints, and it can reach deep occluded surgical targets without colliding in a critical anatomical environment. In surgical robotic operation, less spatial sweeping area from the flexible manipulator in motions is desired to induce the minimal surgical complications. The goal of our research is to reduce unnecessary sweeping motion of the flexible surgical manipulator in operations, and to obtain safer and more reliable reference trajectories. A novel 3-D neural dynamic model is proposed and expected to obtain the safety-enhanced trajectory in workspace with the consideration of minimum sweeping area. In this model, the neural stimulation propagates from the start state to the whole network through the connective weight of manipulator’s sweeping area. According to the results of comparative studies with commonly used planning algorithms in various simulation scenarios, the proposed planning algorithm is validated in terms of effectiveness and safety. Ultimately, the experiments on phantoms and preclinical cadaveric human head show the feasibility of the proposed safety-enhanced planning algorithm.
More Information:

Fault Diagnosis in Image-Based Visual Servoing with Eye-in-Hand Configuration Using Kalman Filter

Abstract
In this paper, the fault diagnosis (FD) problem in image-based visual servoing with eye-in-hand configurations is investigated. The potential failures are detected and isolated based on approximating parameters related. First, the failure scenarios of the visual servoing systems are reviewed and classified into the actuator and sensor faults. Second, a residual generator is proposed to detect the failure occurrences, based on the Kalman filter. Third, a decision table is proposed to isolate the fault type. Finally, simulation and experimental results are given to validate the efficacy and the efficiency of the proposed FD strategies.
More Information:

Force/Torque Sensor for Tele-operated Catheterization Procedures

Abstract

A tele-operated robotic catheterization system can significantly alleviate the surgeons from radiation exposure and fatigue resulted from long standing time with protective suits. Proximal force/torque signals imply the critical information about the contact forces between the catheter and its surrounding structures. This paper presents a compact, cost-effective force and torque sensing device suitable for catheterization procedures to measure the proximal force/torque signals of the input catheter. The device consists of a rotatable and linear retractable mechanism, a laser mouse sensor, and a coil spring. As the stretched, compressed, and twisted values vary due to the sliding joint, the force and torque signals can be computed based on the Hooke’s law. The proposed sensing device has many advantages such as cost-effective, easily miniaturized and customized, and can be extended to the MRI compatible sensors. The experimental results with step response and time-varying loads by comparing to an ATI Nano17 force/torque sensor show that the Root Mean Squared Error (RMSE) for force and torque measurement are 0.042 N and 0.228 mNm respectively.

Video PPT demo

Publications

J. Guo; M. Li; P. Ho & H. Ren Design and Performance Evaluation of a Force/Torque Sensor for Tele-operated Catheterization Procedures IEEE Sensors Journal, 2016, PP, 1-8