Magnetic Tracking in Medical Robotics

Abstract

Biomedical robotic applications with accuracy requirements demand real-time position and orientation tracking, such as in the field of human motion tracking, rehabilitation, surgical instrument tracking, among many others. Among the state-of-the-art tracking technology, magnetic sensing method is an effective technology to provide fast and accurate tracking result without suffering from occlusion drawbacks. Magnetic sensing techniques are used to sense the distribution of a magnetic source field. With the sensing signals, the pose (position and orientation) between the sensor(s) and the source(s) can be estimated according to the magnetic field distribution model. In contrast to other optical tracking technologies in the clinical setup, magnetic sensing has no line-of-sight problem and is easy to be embedded with many instruments. Therefore, it is useful in intracorporeal applications to provide the location information of the tracked targets inside the human body. For this reason, magnetic sensing techniques have potential to further improve the applications of computer assisted surgeries. For example, flexible curvilinear manipulators or endoscopic devices nowadays need to be tracked in real time for better and safer operations. This chapter gives an overview of how the magnetic sensing technology works in the field of medical instrument tracking. After that, the sensing applications will be given in detail. Three typical medical applications will be discussed: (1) magnetic sensing for wireless capsule robots; (2) Current magnetic sensing devices in clinic setups; and (3) magnetic sensing for flexible surgical robots.

More information

Full-text and more information

Tracking Magnetic Particles Under Ultrasound Imaging Using Contrast-Enhancing Microbubbles

Abstract

In this chapter, motion of magnetic particles were captured using ultrasound imaging with contrast-enhanced microbubbles. Ultrasound videos were captured and analyzed by the created tracking algorithm to determine the efficiency and accuracy of the algorithm. It is necessary to ensure an efficient and accurate tracking method of the particles in order to evaluate future in vitro or in vivo applications of the microbubbles, when implanted into an enclosed system and imaged using ultrasound. First, it was found that the porous structure of the magnetic microbubbles could be successfully fabricated based on a gas foaming technique, using alginate (low viscosity, 2% (w/v)) as the polymer, mixed homogeneously with sodium carbonate (4%) solution. The reaction between sodium bicarbonate and hydrogen peroxide (32 wt %) in the collecting solution allowed the creation of encapsulated microbubbles. The alginate went under crosslinking in the collecting calcium chloride (25% w/v) solution. Second, it was proven that the encapsulated microbubbles enhanced the resultant ultrasound images, with the air bubbles appearing as bright white spots. In contrast, the solid spheres appeared dull and at times could not be seen under ultrasound. The contrast enhancing properties of the microbubbles allowed the microbubbles to be detected by the tracking algorithm, as compared to the solid spheres which could not be detected at all. Third, ground truth of the (x, y) coordinates of the microbubble centroids were determined using manual selection by the user mouse. Based on the accuracy analysis done, the accuracy of the tracking algorithm was 3.33 pixels, or 0.0354 cm, between the algorithm detected and the manually selected (x, y) coordinates of the centroids. Also, the optimal number of particles to be tracked was up to five particles with an accuracy studies.

More information

Full-text and more information

Sensor Fusion Of Leap Motion Controller And Flex Sensors Using Kalman Filter For Human Finger Tracking

Abstract

In our daily life, we, human beings use our hands in various ways for most of our day-to-day activities. Tracking the position, orientation and articulation of human hands has a variety of applications including gesture recognition, robotics, medicine and health care, design and manufacturing, art and entertainment across multiple domains. Out of the various tracking methods, vision based tracking is an efficient and widely used method. Several devices have been developed by researchers and engineers to track objects using vision. The Leap Motion controller is one such device. However, visual tracking is an equally complex and challenging task due to several factors like higher dimensional data from hand motion, higher speed of operation, self-occlusion, etc. This paper puts forth a novel method for tracking the finger tips of human hand using two distinct sensors and combining their data by sensor fusion technique. The proposed method is tested using standard human hand gestures and the results are discussed. Finally, a soft robotic gripper was operated remotely based on Leap Motion hand tracking and the proposed sensor fusion method.

More information

Full-text and more information

Design, Characterization and Applications of a Novel Soft Actuator Driven by Flexible Shafts

Abstract

This work presents a novel soft actuator with a 3D-printed elastic body based on a fused-deposition-modeling technique and with tendon actuation based on flexible shafts, which allow push, pull, and twist torque transmissions. The combination of the soft body and flexible shaft furnishes an easy-making, modular and functional unit that possesses softness and enables three degrees of freedom. We derive the kinematics and statics of the actuator based on the assumption of piecewise constant curvature, and identify the parameters experimentally. To understand the performance of the soft actuator in different design and fabrication settings, extensive experiments are performed to compare different shapes of cross sections, infill densities, infill patterns, dentation structures and moment arms in terms of generating forces under the same pulling forces. In addition, experimental validations are performed to characterize other properties such as workspace, hysteresis, pushing force, transmitted torque, and tip force under both bending and twisting. Finally, three potential applications, i.e., a soft robotic hand, a multisegment continuum robot, and a miniaturized drilling device, are prototyped and presented experimentally where the flexibility endowed by the shafts is demonstrated and highlighted. The scalability and modularity are also showcased in the three applications.

More information

Full-text and more information

Soft robotics with compliance and adaptation for biomedical applications and forthcoming challenges

Abstract

Biology has always motivated engineers to come up with efficient and reliable machines to move in complex environments. The dexterity, softness, and body compliance of natural system such as cephalopods or caterpillars have inspired robotic engineers to incorporate soft, deformable materials such as gels and elastomers into their designs. Hence, the inception of soft robots shifts the paradigm and trends in robotics, which could potentially revolutionize health care, human–robot interaction, field exploration, rehabilitation, and related applications. Throughout this review article, we have restricted our discussion to the applications of soft robots in biomedical domains exclusively and the perennial challenges faced therein.

More information

Full-text and more information

Soft robotics with compliance and… (PDF Download Available). Available from: [accessed May 30 2018].

Topology Optimized Design, Fabrication and Characterization of a Soft Cable-driven Gripper

Abstract

Soft-bodied robots, due to their intrinsic compliance, have shown great potential for operating within unstructured environment and interacting with unknown objects. This paper deals with automatic design and fabrication of soft robots. From a structure point of view, we synthesize a soft cable-driven gripper by recasting its mechanical design as a topology optimization problem. Building on previous work on compliant mechanism optimization, we model the interactions between the gripper and objects more practically, in form of pressure loadings and friction tractions, and further, we investigate how the interaction uncertainties affect the optimization solution by varying the contact location and area. The optimized soft fingers were 3D printed and then assembled to build a gripper. The experiments show that the gripper can handle a large range of unknown objects of different shapes and weights (up to 1 kilogram), with different grasping modes. This work represents an important step toward leveraging the full potential of the freeform design space to generate novel soft-bodied robots.

More information

Full-text and more information

INI: Electromagnetic needleless injector with halbach array towards intravitreal delivery

Electromagnetic needleless injector with halbach array towards intravitreal delivery

IEEE Access 2017

Abstract

The fear of pain and needles deter some patients from seeking intravitreal treatment, which drives our group to develop an needleless device for performing intravitreal injections. A prototype for an electro-magnetically actuated needleless injector, based on Halbach arrays, is described and characterized in a lab setting. The implication of the prototype for needleless ocular drug delivery is investigated. This investigation is intended to eventually improve drug delivery of glaucoma medication enabling safe needleless approaches. We detail the design aspects of the injector and characterized the device with custom-made phantoms. It was observed that, despite delivering the drug bolus to the center, the viscous vitreous phantom indicated vorticities similar to counter rotating vortex pairs, which could damage the retina. The observed peak velocity during the phantom experiments was 6.1mm/sec at the retinal layer, indicating that the delivery bolus can impart shear forces to the retina via the vitreous.

 

Design and Characterization of an Electromagnetic Needleless Injector Based on Halbach Design Towards Intravitreal Delivery

Supporting videos

> 1-minute short video demo

> full video demo

Appendix

The results comparing the measured Fz, the force in the normal direction to the sensor surface, and Mag, the magnitude of the force vector, across the various depths of injection and at the two voltage points.

fig24fzmag15v20v
Fig 24.  Left (15V) Right (20V); Top (Fz) Bottom (Mag)

Comparison between the four depths did not show significant differences:

Changing the distances between the sensor surface and the injection nozzle does not appear to have a distinguishable relationship. Note: each data plot is the average from 3 data samples. This is indicative of the following; regardless of the size of the orbital, the peak force observed is going to be dependent on the injectant properties. We note that more experiments should be done for characterization of distances between 20mm and 12.5mm, we did not test this range due to concerns over damaging the sensitive ATInano17, and hence the initial expectation of measuring 20 to 35mm and anticipating an extrapolate-able relationship. The rational for these distances assumes an orbital diameter of 25mm and the drug is delivered to the center at 12.5mm. The 25mm distance is likely to be near the retinal layer and 20mm would be in between.

Test in phantom chamber:

The dimension of the vitreous phantom chamber is a cylinder with height 17mm and diameter of 25mm. This relates to a volume of approximately 8345uL. This is significantly larger than the vitreous volume in human eyes. Assuming the human vitreous to be 4000uL, the height of our cylinder should be 8mm. In such a scenario, the rotational symmetry in the spherical orbital is lost and hence the flow will be more a keen to a 2D planar flow rather than a 3D flow. Our selection of 17 mm was a compromise between maintaining the 3D flow while allowing an observable 2D slice of the injection profile. In addition, the selection of the 10.9 mm by 17 mm access point is arbitrary. Its purpose was to allow ease of filling and removal of vitreous phantom while maintaining the spherical shape as much as possible. The current dimensions relates to a chord at 11.25mm from the center of the circle, thus maintaining at least 95% of the diameter.

 

Related Publication

Electromagnetic needleless injector with halbach array towards intravitreal delivery (in press) IEEE Access, 2017

Simultaneous Robot-World, Sensor-Tip, and Kinematics Calibration of an Underactuated Robotic Hand with Soft Fingers

IEEE ACCESS. PREPRINT VERSION. ACCEPTED Dec, 2017

Simultaneous Robot-World, Sensor-Tip, and Kinematics Calibration of an Underactuated Robotic Hand with Soft Fingers

Ning Tan, Xiaoyi Gu, and Hongliang Ren Senior Member, IEEE

Abstract—Soft robotics is a research field growing rapidly with primary focuses on the prototype design, development of soft robots and their applications. Due to their highly deformable features, it is difficult to model and control such robots in a very precise compared with conventional rigid structured robots. Hence, the calibration and parameter identification problems of an underactuated robotic hand with soft fingers are important, but have not been investigated intensively. In this paper, we present a comparative study on the calibration of a soft robotic hand. The calibration problem is framed as an AX=YB problem with the partially known matrix A. The identifiability of the parameters is analyzed, and calibration methods based on nonlinear optimization (i.e., L-M method and interior-point method) and evolutionary computation (i.e., differential evolution) are presented. Extensive simulation tests are performed to examine the parameter identification using the three methods in a comparative way. The experiments are conducted on the real soft robotic-hand setup. The fitting, interpolating, and extrapolating errors are presented as well.

Index Terms—Soft robotics, calibration and identification, robotic hand, AX=YB, hand-eye calibration, tendon-driven robot